  • A GUIDELINE TO ECONOMICAL HEATING SYSTEM UPGRADES

    Reviewing all of our installations in recent years, every customer has reported fuel usage reduction of 40% and more. Impressive — and yet humbling. More importantly is how we have achieved these and sharing our experiences with others.

    Predicting the economics of an energy efficiency product, whether you’re proposing insulation, window or heating upgrades is a difficult and potentially an “egg-in-your-face” task. It would seem that claims range from the modest to the scientifically unachievable, qualified only by the sales skill of the presenter. Ultimately, putting it down on paper is the only real documentation. Admittedly we are conservative as well, opting on the side of caution, but predictable. In reality all of the energy product upgrades in combination must be considered.

    It has also become apparent that we personally are in a niche market by default. The predominant activity of “swapping boilers” by dealers and service tradesmen eludes us. We seem to get the “tough ones”, and love it! This also provides us with a developed and unique skill-set to apply. Watching the online forums and fielding direct questioning reinforces this contention. Also consider that our commitment is to efficient, high-end hydronic (hot water) oil, propane and natural gas heating systems by Weil-McLain ONLY, and more specifically their Ultra Series. Reading our prior blogs on this website will clarify and further detail our activity.

    ALWAYS CONSIDER YOUR HEATING REQUIREMENTS AS PART OF A SYSTEM. By a system we mean all of your energy requirements, typically heating (and cooling), domestic hot water, pool heating, spas, etc. Firstly,

    1. You must define where you are now, heating-wise
    2. Where do you intend to go, then
    3. How are you to get there?

    In simplistic terms, your heated space is a “box” to be maintained at a comfortable temperature regardless of external influence. The influences to the “box”, in general order of importance are:

    1. Infiltration: Air leakage is the most significant robber, moving both warmed and exterior air into and out of the structure. Seal these as much as possible. The technical measure is ACH (Air Changes per Hour) and is difficult to field measure, requiring substantial equipment. An ACH of 1 is considered good, 2 or more poor and below 1/2 or so requiring air exchange. Things can get too tight — and unhealthy!
    2. Cap Insulation: Heat rises and consequently the ceiling level temperatures and hence losses are significant.
    3. Windows & Doors: Energy efficiency of these has improved significantly in the last 25 years or so and can substantially improve things. Note that Infiltration (No. 1) is a significant consideration of these as well.
    4. Sidewall Insulation: The remainder of the vertical heated exterior wall structure.
    5. Sills and Floors: Tightened structure to the ground (and below) level, including basement windows & doors.

    To determine where you are (or plan to go) requires measuring the “box”, hence using a Heating Loss Calculator.  (Refer to our prior blog on its use.) In so doing you can “play the numbers” by changing values therein to determine effect(s) and hence a strategy. This is the standard tool of Heating Professionals and some free software is available on-line. Don’t let it scare you. If you can use a measuring tape, fill out a form or translate a recipe you’ve got it made. If you’re still bashful let that geek kid loose at it.

    The Heating Calculator not only tells you where you are but where you are going, as prior mentioned. Remaining then is how do we get there?

    AGAIN OUR TENET: ALWAYS CONSIDER YOUR HEATING REQUIREMENTS AS PART OF A SYSTEM. You have many tools to work with, not just replacing a boiler or a furnace to satisfy all of your energy requirements. Again consider ALL available tools to meet your heat energy requirements and maximize efficiency. Generally, they are:

    1. Furnace — A fuel fired appliance that heats and circulates warmed air to maintain comfort.
    2. Space or Unit Heater — A self-contained gas or oil-fired heated air appliance dedicated to a room area.
    3. Air Handler — A furnace that utilizes an internal heater (electric, hot water or steam) supplied by an external energy source (wired or piped to it).
    4. Boiler — A fuel fired appliance that heats and circulates heated water (or steam) through radiation to maintain comfort.
    5. Heat Exchanger — A device to transfer heat from a differing medium to another without mixing and therefore isolating them. (Useful for special environment applications and situations that we will detail.)
    6. Tankless Heater — A coil immersed internally into a boiler to also provide domestic hot water service.
    7. Indirect Heater — A detached water storage tank heated by a boiler to provide domestic hot water service.
    8. Demand (Instantaneous) Heater — A gas-fired appliance that heats domestic water on demand (no storage).
    9. (Common) Water Heater —- A fuel fired (electric, gas or oil) appliance that heats domestic hot water directly.

    As you review your requirements in lieu of these tools, you will note that there are two (2) distinct scenarios:

    1. Separate appliances for heating and hot water. (A furnace or space heaters with separate demand or common water heaters in combination to suit your local and peculiar fuel economics.)
    2. A combination system utilizing a single fuel source boiler providing all demands.

    First, determine fuel selection. Referring to our other blogs you will note that we are in the higher heating demand New England, and are further restricted by available fuel options and economics. Briefly, in cost order:

    1. Electric rates are very high and not considered for efficient area or domestic hot water heating.
    2. Propane (LP) is generally available but of significantly higher cost as a heating fuel. It is considered a fuel-of-choice, typically providing cooking and/or hot water requirements.
    3. Natural gas has limited availability but is currently the lowest cost heating fuel option. Where available, its choice is obvious with a single caution: Get an actual billing estimate! As a distributed fuel (like electricity) its total delivered cost will be higher than the mere cost of the “fuel”.
    4. Fuel oil is predominant and is a low cost option, competing with natural gas only. Note: Heat pumps, photovoltaic, geothermal, wind and solar are very economically protracted options and not considered currently competitive.

    Scenario 1 (FHA Furnace & Separate Water Heater) can be well executed particularly where natural gas is available and used in “Demand Appliances” i.e. Condensing Gas Furnaces @ 95% and “On-Demand” Water Heaters @ 83%. Propane (LP) efficiencies are of course similar, but at a significant fuel cost premium.

    Scenario 2 (Single-source FHW Boiler) offers the most viable option both economically and physically and is the basis for our system configurations. Selecting the most cost-effective fuel, an efficient appliance to convert, the best medium to distribute and the appropriate devices to transfer energy equate to a “win-win” solution. Using water as the heating medium is ideal for efficient and flexible distribution. Specifically:

    1. A Condensing Gas Boiler @ 93+% or a Triple-Pass Oil Boiler @ 87% providing the heated water.
    2. An Indirect Water Heater providing Domestic Hot Water efficiently and on-demand.
    3. Conventional Radiation to warm full usage areas.
    4. An Air Handler to adapt existing FHA (Forced Hot Air) ducting and distribution without alteration, or to heat an occasional usage area where cold and/or freezing is not detrimental in the off-use cycle.
    5. A “Plate” Heat Exchanger to adapt heated water to physical conditions:
      • Freezing applications such as deep cold areas, selective seasonal shutdowns, snow removal and some pool applications by using glycerol (anti-freeze) as a medium without passing it through the boiler.
      • Adapting zero-pressure sources (steam and exterior wood boilers) to deliver to pressurized systems.
      • Couple a cold-environment source such as an external Solid Fuel Boiler (Wood/Coal/Corn/Peat, etc.) to hydronic (hot water) distribution.

    Existing Systems vary widely in configuration and so must be approached individually. However there are a few distinct patterns and approaches:

    1. The existing Scenario 1 above, i.e. a Forced Hot Air System and Conventional Water Heater. Consider a High-Efficiency Boiler, an Air Handler and Indirect Water Heater combination. This is typically a one-step option — all or nothing vs. individual unit upgrades.
    2. Let’s call this Scenario 2A. An older, inefficient boiler system in poor condition and in need of replacement. Upgrade in entirety when the existing boiler (the high-ticket item) is in jeopardy and fuel efficiency is poor.
    3. Scenario 2B is an existing stand-alone boiler in fair shape with either an internal Tankless Heater or a detached Conventional Water Heater. This common combination offers a step approach to higher efficiency. Consider replacing your Domestic Hot Water Source (Internal Coil or separate Heater) with an Indirect Water Heater and converting your boiler to a “Cold-Start”, On-Demand System. This requires additional plumbing and wiring but you now have attained most efficiency gains minus the boiler efficiency gain itself. Stand-by heat losses are now minimized. You’ll love the savings.

    A story to make our point. We replaced an old, terribly over-sized boiler recently with raves from the customer — with one exception. An adult daughter had moved into an open room next to the “Old Dragon” in the basement. Now she is cold. The next step is to finish off the basement and provide heat only where it is needed (and more efficiently).

    This analogy brings us to our last point. As you make energy improvements to a structure you do two (2) things:

    1. You improve its energy efficiency, the desired result. But,
    2. You also effectively increasingly oversize your boiler for your heating application, an undesirable result. Considering that the Old Dragon was likely over-sized by practice initially, you are now incurring very substantial “stand-by losses”. These energy losses up the chimney, into the surrounding area and poorer energy conversion become substantial indeed, inviting the greater improvement opportunity. Change the boiler.

    We trust this is of some help to you in assessing your energy needs and determining a course of action.

    Last Edit: 10/12/2012 pdm


  • BOILER RUNS JUST FOR DOMESTIC HOT WATER – WASTING ENERGY!

    During the heating season, having an Immersion Coil in your Boiler to provide Domestic Hot Water (DHW) makes a lot of sense. You are utilizing the hot water present in your boiler for area heating to additionally provide hot tap water at a very reasonable cost.

    But what about when there is low or no area heating demand? Your boiler is still hot (typically between 160 and 190 degrees F) waiting to provide occasional domestic hot water (at about 120 to 140 degrees F). Meanwhile the boiler stays at temperature, radiating heat into the boiler room and leaking heat up the chimney, neither of which can be utilized.

    A commonly used trick to save energy during the low demand period is to turn off the boiler entirely using the Emergency Switch (usually located near the main hallway door, but may vary). When hot tap water is needed the boiler is switched on and provides hot water within 15-20 minutes, typically. After use the boiler is again switched off. The really thrifty have learned to shut off the boiler before the last shower or then run the dishwasher to utilize the remaining boiler heat to advantage.

    The efficiency answer is an Indirect Water Heater, a super-insulated storage tank heated by your boiler and substituting for your Immersion Coil. The best of these are made of stainless steel, super-insulated to lose about 1/2 degree F per hour and have lifetime warrantees. Additionally your Boiler Aquastat Control (controlling boiler temperature) should be changed to a “Cold Start Aquastat”, allowing it to heat ONLY when area heating or Domestic Hot Water is demanded or used to maintain tank temperature. Your boiler is now an “on-demand” type, lowering toward room temperature between cycles.

    This storage of a quantity of heated tap water not only gives you instantly available hot water at any time but is inexhaustible, with your boiler cycling to meet any demand. No more initially hot water that cools down quickly with use caused by under-sized or sediment-clogging Immersion Coils either. Yes, the thrifty can still use the Emergency Switch trick for additional savings. In fact, one family of four with two young boys has found that they need only switch on every two days in the summer after several showers, dishwasher, wash the dog, etc.

    Your boiler runs less and runs cooler on average too, prolonging its life while reducing radiated and chimney drafted heat losses. Efficiency gains all around.

    Note: This argument also applies to separate Electric, Gas or Oil Hot Water Heaters by incorporating them into a managed, single fuel system.

    Last Edit: 10/10/2012 pdm