  • DELTA-T ECM HYDRONIC DISTRIBUTION – Really “Raising The Bar”!

    Heating and moving water (hydronics) is recognized as the most efficient method of creating and distributing warming energy. From the Roman Baths to Gravity Piped Hot Water Systems of a century ago natural convection of heated water provided a simple, if seemingly temperamental solution.

    Adding pumps (circulators) to heating water distribution has forever improved comfort an flexibility. However, their application has been less than ideal, utilizing only fixed-speed/capacity circulators, typically poorly applied to residential heating in particular. Using a “one size fits all” approach and swapping sizes to effect results has been a thorn to the trade suppliers.

    Applying switchable, multi-speed circulators has provided an interim solution to poor matching options. Further, measuring actual circulator zone supply and return temperature differentials with an infrared thermometer while selecting speed(s) has provided a more efficient solution. It’s still a less-than-ideal result, with a cost premium.

    The Delta-T (Differential Temperature Sensing) Variable Speed Circulator has been around for some years now, providing the idealized solution to heating distribution flow management. It has arguably fallen far short of its potential, burdened by high initial cost, audible operational “whine” and low speed “growling”. Occasional high load torque stalls further contributed to its unknown nature.

    Enter the ECM (Electronically Commutated Motor), the latest iteration of the “intelligent” Delta-T Variable Speed Circulator. The “heir apparent” is whisper quiet yet powerful, dramatically reduces power consumption with no “torque stalls”, displays great functional data and at a palatable cost. Taco® Comfort Solutions of Cranston, RI also claims up to 15% fuel savings along with an 85% energy drop with their 00e Series VT2218 ECM Circulator, pictured.

    Author’s Note: We former High-Tech Process Engineers were applying “Stepper Motors”, the ECM predecessors to Machine & Process Control over 40 years ago. Finally, the Heating World is getting some real tools to work with!

    The Delta-T Circulator is and has always been marketed as an enhanced replacement for a fixed or multi-speed circulator. Have a zone performance issue? Substitute a Delta-T and “tweak” it in. Problem fixed, within the constraints of the zone design and a 3X cost premium of course. This latest (and supplier exclusive) Taco® VT2218 is being very well received, breaking the “Cost-Performance Stigma” of its predecessors and counterparts. We love it!

    VT2218+ZV ultra-oil-1 HTPSuperstor

    As “High-Tech” Process and Manufacturing Engineers with a Heating Discipline we (Mercier Engineering) have further projected the Taco® Delta-T ECM VT2218 as a Dedicated System Circulator, the acknowledged INDUSTRY FIRST to do so! Reviewing its Technical Specifications the VT2218 is ideally suited to residential/light-commercial heating system applications, given that operational attributes can be accommodated. These are namely:

    1. Providing uniform heating performance under normal multi-zone demands.
    2. Simultaneously servicing an Indirect Water Heater (IWH) to optimize both domestic hot water (DWH) and heating water generation.
    3. Prioritizing DHW generation within varying area heating demands.
    4. Accommodating differential temperature branching such as radiant zone(s).
    5. Satisfying both current and future (planned expansion) demands without an efficiency penalty.
    6. Providing beneficial System Service & Reliability projections.

    Over the past fifty (50) years we have installed and monitored “conventional” hydronic (FHW) heating systems, focusing on component selections, their performance and service levels. This continual qualification process has yielded a set of Premium American Components with “zero-fail” histories, at the expense of other NAFTA, Euro & Chinese products.

    Recognizing the potential of Delta-T Hydronics Distribution as previously noted, about five (5) years ago began a concerted effort to select and qualify the dedicated system circulator application. Our independent work using three (3) successive iterations of Taco® VDT, HEC and VT/00e Products has yielded not only a viable, but a superlative Packaged Delta-T ECM Hydronic Heating Appliance™. Its performance is principally based on our Proprietary Near-Boiler Piping System that constitutes the basis of our Non-Provisional Intellectual Property Protection Submission (Patents Pending – USA & Canada).

    So what began as an “evolutionary” effort to apply a newly available “tool” in the resultant has approached a “revolutionary” one. Our Packaged Delta-T ECM Hydronic Heating System™ is actually a FHW Heating Appliance, an industry first! Placing the Delta-T ECM Circulator into a full hydronic (FHW) heating system we slogan as“Putting an ‘Automatic Transmission’ on a Boiler”. Coupling “intelligent” Taco Zone Sentry®valving (pictured), a “high-mass” boiler (Weil-McLain UOpictured)and an integrated IWH (HTP SSU45– pictured)dramatically reduce complexity and idealize hydronic system performance.

    In our introduction we referenced the “natural convection” (gravity heating) used by the Romans, et al that prefaced our “modern” hydronics. Our optimized Delta-T ECM System exhibits exceptional gravity convection qualities, continuing heating upon circulator disablement or with zone valve manual operation. Short of a full electrical outage significant gravity convection heating continues, providing a useful fail-safe protection feature.

    Now let us really “Raise The Bar”. Here is performance data taken from two (2) similar “beta test sites” in our grouping.

    100,000 BTUH System, Oil-Fired, 3-Heating Zones + IWH

    Attribute “Conventional” System Delta-T Hydronic System Comments
    System Efficiency (Est.) 87% (Boiler Only) 90++% (Aggregate) Combined Hydronic Efficiencies
    Mean Operating Temperature > 145°F (Est.) 132-140°F (Observed) Normal Heating Operation
    Distribution Power 165 Watts (Est.) 11-12 Watts (Observed) Equates to Taco® Claims
    Distribution Fuel Efficiency  N/A – 15% Consumption Per Taco® Claims
    Natural Convection  Minimal to Moderate Very Significant (Observed) Very Installation Dependent
    System Footprint < 35 Sq. Ft. 12 Sq. Ft. (Actual) Very Installation Dependent
    Construction/Life Low-Mass C.I. or Stl. + Copper High-Mass C.I. & Stl. Only  10 to 20 vs. 30+ Yrs. (Est.)
    Complexity/Maintenance/Skill Higher/Annual/Specialized Low/Bi-Annual/Standard Standard Controls Only
    System Installed Cost (Est.) $10,000+ (Est.) $7,500 (Quoted) Southern NH Region

    This is the new “Bar Height”.

    We challenge ANY Tradesman or System Installer to raise it.

    To Summarize:

    1. Delta-T ECM Hydronic Distribution is singly the most significant and cost-effective contemporary heating advancement.
    2. This technology is applicable to any fueled hydronic heating system with substantial packaging and cost benefits.
    3. System configuration using a Dedicated Delta-T ECM Circulator further reduces physical and technical complexity while idealizing hydronic performance.
    4. Our Packaged Delta-T ECM Hydronic Heating System™ is the first, true Hydronic Heating Appliance, considering its intrinsic architecture, performance and as-installed economics.
    5. This is the new Standard of Measure in Hydronic Heating.

    Author’s Note: Updated 06/12/2017


  • BEYOND AFUE’S – TOWARD REAL HYDRONIC (FHW) HEATING EFFICIENCY!

    For the past year Mercier Engineering has been immersed in developing and preparing for market it’s Packaged Delta-T Hydronic (FHW) Heating System™, based on our past heating experience projected into the new world of “Delta-T Circulation”. You may have noted our preoccupation with this technology in “The Heating Blog” on our www.boilersondemand.com  website. Time to “put our money where our mouth is”, so to speak. The results of our efforts we deem noteworthy and are initially reflected in this writing.

    As the titling of this blog purposely implies, we must get beyond weighing hydronic heating system efficiencies solely upon the boiler’s Annual Fuel Utilization Efficiency (AFUE) Rating.  It is only one of multiple elements in an operational formulation that is seldom if ever approached, even more poorly understood, and we allege almost universally misapplied. Strong words which must be tempered by the reality that there has been little market incentive to change our approach to serving the residential FHW heating market in particular; but we ultimately must adapt and change it for the consumer’s benefit.

    AFUE is a regulatory, laboratory testing procedure intended to establish an efficiency value for a hydronic (hot water generating) boiler under a defined operating sequence and conditions. It can be presumed that it executes this comparison very effectively, under its terms. However, what it does not measure from our observations is in practice very significant. Specifically these Non-AFUE Test Attributes are:

    1. There are no provisions for qualifying or measuring between-cycle “stand-by” or “idle-time” losses. This is the time between burner firing cycles when the boiler is prone to radiated energy and convective exhaust (flue) losses, presumed to be non-productive.
    2. Similarly, the testing is “steady-state” in execution, providing no qualification or quantification of individual boiler attributes that may contribute to site application efficiency.

    These test attribute observations have been borne out in field applications, where system performances have not correlated well, boiler-to-boiler or system-to-system. To further complicate this is the variability of physicals to each application, however subtle. The forums and blog sites are rife with these seemingly “apples-to-oranges” commentaries. Our developmental efforts may be able to provide some explanations.

    From our observations there are necessarily five (5) elements contributing to total system energy efficiency:

    1. The boiler (heat engine) energy conversion efficiency or AFUE.
    2. The physical attributes of the specific boiler complimentary to system operation.
    3. The energy required to move heated water through the distribution system (radiation).
    4. The effective matching of radiation elements to heating demand.
    5. The control algorithm(s) to match energy creation with varying system demands.

    Our initial efforts have been with oil-fired hydronic systems and is the focus of this document, with gas-fired and solid-fuel applications to follow as resources permit. However, much of this effort is applicable as the basis of other heating systems.

    Varying the output (energy creation rate) of any heating resource is paramount. This has been readily achieved in gas-fired boilers by “modulating” combustion with sophisticated valving and controls. Typically they adjust from 20 to 100% of capacity, from “idle” to “full speed” to use the automotive analogy. However, direct modulation of oil-fired systems is not feasible using current technologies. A fixed (capacity) firing rate via pressurized, nozzle induced fuel atomization is the norm. Therefore, the only option is to adjust the operating temperature of an oil-fired hydronic boiler via controls to compliment heating demand. This is reasonably well-managed with modern “cold-start” aquastats, external temperature sensors, etc.

    The prior unaddressed penalty to particularly residential hydronic systems has been the toll on equipment and electrical energy requirements of circulating heating water with fixed-speed circulators. They are notoriously and arguably universally misapplied and inefficient in practice. Reducing water temperatures merely aggravates the situation by prolonging circulator cycling.

    Fortunately technology has come to the rescue in the form of the “Delta-T” Circulator, now becoming very applicable and affordable to the residential/light commercial markets. The undisputed pioneer and flag-bearer in this market is the Taco Viridian VT2218 found at this link: http://flopro.taco-hvac.com/media/Viridian_VT2218_100-114.pdf  To use the quote “This changes everything” is not an exaggeration! The Viridian is in fact the second generation, replacing the entry product Taco “BumbleBee” found at this link: http://www.taco-hvac.com/uploads/FileLibrary/100-101.pdf We mention the “BumbleBee” only because it has rapidly become a “cult product” in the HVAC Community, somewhat akin to the “Trekkies”. It was our initial “new tool” in developing and thence refining our product(s). Like our brothers, we hate to see it go as we move to the refined and more sophisticated “Viridian”.

    Referring back to our five (5) elements to total system efficiency, Delta-T Circulation is number three (3) on the list but is deservedly and necessarily the foundation of any hydronic system improvement. Taco reports system Delta-T Circulator-only swaps yielding 15% fuel usage reductions. It is the keystone of our Packaged Delta-T Hydronic (FHW) Heating System™, and should be the first improvement to any system! We caution however that this will require substantial near-boiler system re-piping and your installer must be knowledgeable. It is discouraging to note how few of our fellow tradesmen are cognizant of Delta-T or have used it beyond a radiant heat loop. We “Old Dogs must learn new tricks”, and we have!

    The second element of import is the necessity to employ “Cold-Start” Boiler/Aquastat Hydronic Technology, which overlaps Nos. 2 and 5 in our list. We are unabashed in our praise of the Hydrolevel 3250-Plus “Fuel Smart” Aquastat, found at this link: http://www.hydrolevel.com/new/images/literature/sales_sheets/fuel_smart_hydrostat_sales_sheet.pdf   It is now standard equipment on all our Weil-McLain Ultra Oil Boilers, and none too soon! The inter-action of the 3250-Plus with the VT2218 Circulator’s operational software is paramount to total system performance, as we have learned.

    Note: “Cold-Start” Technology applies to “heat-only” boilers. DHW (Domestic Hot Water) must be effected by an external Indirect Water Heater or another dedicated appliance. We combine the Indirect Water Heater in our design for optimized Heat and DHW Generation.

    Element 3: Our development indicates individual boiler attributes are significant. Specifically,

    1. Boiler supply and return tap placements are crucial to system “packaging”, i.e. the ability to compactly (efficiently) structure near-boiler piping. (We can pipe into a space as close as 11″ from the chimney, with all piping and controls behind the boiler, yet readily accessible.)
    2. A very high boiler mass (weight) for its capacity, i.e. for both thermal damping and storage.
    3. Favorable exchanger flue passage routing and exhausting.
    4. Burner type to compliment its attributes.

    The noted attributes lead us to our “Boiler-of-Choice”, the Weil-McLain Ultra Oil Series with the Beckett NX Burner. Refer to this link for detail: http://www.weil-mclain.com/en/assets/pdf/Ultra%20Oil%20Brochure_8%20Pg_web1.pdf   We have had “conventional” system design and installation experience with this boiler for over ten years now, with only one “no heat” service call, a failed aquastat. Weil-McLain has since upgraded it to the Hydrolevel 3250-Plus, thank God!

    The Beckett NX Burner has been likewise flawless in operation. Literally a “plug and play”. Its dual vent typing capability (direct & chimney) has proven beneficial to problematic venting applications, especially when encountering “cold chimneys” in our northern climate. Fully exposed exterior chimneys are sure to give a rough startup without utilizing its pre-purging and pressure firing features.

    The key attribute to system performance outside of Delta-T Distribution has proven to be Thermal Mass (Storage) provided by the sheer robustness (weight) of the Weil-McLain UO Series High-Mass, Triple-Pass Boilers. They are “The Heavyweight Champions” by far and as a result exhibit lower mean boiler operating temperatures and very less frequent burner cycling.

    As a matter of policy we do not cite or criticize our competitors, but we must make a single attribute comparison to emphasize our point. The approximate block weights of the top hydronic (approx. 100KBTUH, 87% AFUE) oil boilers are:

    Manufacturer/ModelApprox. Ship Wt.
    less Tare (lbs.)
    % of HighestComments
    Buderus G115/G21537560%Adjusted for 100KBTUH
    Burnham MPO-IQ11545072%
    Weil-McLain UO-3625100%

    AUTHOR NOTE: Very noteworthy, the Weil-McLain UO is also disproportionately the lowest cost per pound (by nearly half) of the three. Just what is the consumer paying for, we wonder? In our development experience increased boiler mass equates to improved system longevity and hydronic performance!

    Radiation (Element 4) efficiency is the remaining, but least controllable variable in a heating system. It is substantially outside the scope of our system application, yet there are some performance elements we can address.

    Existing hydronic radiation:

    1. Removal of unnecessary valving in zone supplies and returns. All zone supply functions are integrated into our system package.
    2. Zone interconnection and functionality can be optimized by correct pipe sizing and routing. It confounds us as to why some plumbers use virtually no 45° fittings! You can use 3-4 of them vs. a 90° elbow for the same flow resistance, and only 70% of the pipe required for a 90° elbow routing.

    New hydronic radiation:

    The contemporary approach to radiation varies widely, from simple radiation loop(s) for zoned heated areas to individually heated rooms throughout. The more finite the control, the more piping, fittings and control valving, the more hydronic distribution energy is required.

    Ironically, the same Delta-T Circulator Technology we employ to maximize our system performance has preceded us and become the darling in particularly radiant system applications. We have also employed them in these and they perform admirably. They reduce the energy requirements significantly but yet still camouflage that basic issue.

    If your concern is total energy consumption of a system, we would invite you to consider using less sophisticated radiation distribution schemes. A properly designed, installed and balanced series or split piping loop exudes simplicity and will likely be a lower installed cost. The KISS Principle applies — keep it simple ….. (Refer to our Heating Blog Library for additional detail.)

    To Summarize:

    1. Additional Boiler Attributes are important, beyond the AFUE Rating. In particular heat exchanger thermal mass (weight) will lengthen service life while minimizing repair costs. Burner attributes related to exhausting and tuning must also be considered.
    2. Delta-T ECM Hydronic Distribution Technology is key to improving any system’s energy performance, both heating fuel and electrical power consumption.
    3. Inter-related “intelligent” controls determine system operational performance. They are currently the Hydrolevel 3250-Plus Boiler Aquastat and the Taco VT2218 Delta-T Circulator Logic.
    4. Near-boiler plumbing in particular affects system performance. This is optimized in our system piping configuration to include fail-safe “natural gravity convection”.
    5. Interconnections between our system zone access points to existing radiation must be executed with the goal of minimizing flow anomalies.
    6. Existing and/or new radiation installations must likewise be executed by idealizing flow conditions inasmuch as possible.

    References:
    We strongly recommend referring to Taco’s website link http://flopro.taco-hvac.com/deltat_resources.html and refer to the various Delta-T resources therein. There’s a volume of resources here that will properly inform you of this new technology and its place in your Hydronic (FHW) Heating System.

    Author’s Note: Hyperlinks updated 08/27/2019


  • WHAT IS A DELTA-T SYSTEM?

    A Forced Hot Water (FHW) Heating System is designed to efficiently provide energy distribution to heated areas. This is accomplished by combusting fuel in a boiler and moving the heated water through radiation to warm the desired environment.

    However, to accomplish this most efficiently requires:

    1. A high-efficiency appropriately sized and fired boiler.
    2. Properly proportioned and positioned radiation for each heated area.
    3. Idealized, simultaneous energy delivery of heated water to all radiation, irrespective of heating demand patterns.

    Practically however, none of these elements are absolutely correct, nor can they be. Boilers and radiation are almost never idealized for efficiency, but the third (energy distribution) is typically the most poorly executed of all. You must deliver heated water at an ideal rate for maximum heating transfer efficiency.

    Common distribution systems typically consist of:

    1. Dedicated circulators for each zone, or
    2. A common circulator with a zone valve for each zone.

    These configurations do not perform efficiently in practice, and in particular zone valves.

    “Delta-T” is a technical connotation. “Delta” (from the Greek letter ∆) is difference, or differential. “T” designates temperature. Thus Delta-T (∆T) is “differential temperature”.

    The Delta-T Continuously Variable Speed Circulator  employs temperature sensors attached to the boiler supply and returns points. It measures and maintains the ideal temperature differential by infinitely adjusting its water delivery rate (pump speed) to suit. Coupling with the new Low Energy, High Flow Zone Valves this technology maximizes the efficiency of any hydronic system with dramatically reduced electrical power consumption.

    VT2218+ZV

    Additionally, this system also smooths the performance of your existing radiation by typically eliminating hydronic whistle from over-sped, heating lag and imbalance from under-sped zones.

    No costly control system is necessary! The innate intelligence of the Delta-T Circulator teamed with the self-diagnostic capability of this new generation “Green” Zone Valve simplifies wiring, installation and diagnosis.

    It’s a Terrible System. Terribly Simple – Terribly Efficient!