• Tag Archives Automatic Transmission
  • DELTA-T ECM HYDRONICS – Redefining “The Plumber’s Playground”

    Hydronic heating comprises warming water as a medium, moving and expending its energy to warm an environment. Thus we have boilers as heat generators and radiation to convert heated water into warmth. Between these we must distribute our medium via pipes, pumps, valves and controls to meet heating demands.

    Basic hydronic system design rules of course must apply, but by and large the final product interpretation has been left to the tradesman/installer. This individualization provides a very attractive latitude of self-expression. Like an artist painting on a new canvas individual skills, styling and practice all comprise the final “picture”, with the author’s “signature” applied. Based upon our field observations we have come to refer to hydronic distribution in particular as “The Plumber’s Playground”, and with no apologies offered.

    Unfortunately the Laws of Physics apply equally to hydronic system installations as to any other enterprise. Therefore that maze of pipes, valves, circulators, controls and wiring evidenced in a “plumbers playground”, no matter how pretty, daunting or impressive is unnecessarily complex, costly and under-performs. In fact any system installed within the past three years or more not employing Delta-T ECM Hydronic Distribution Technology specifically is woefully under-performing!

    The Heating Game has changed, led by the Taco® Delta-T ECM VT2218 Hydronic Circulator and its supporting Taco® Zone Sentry Valves. We refer to it as “The Hydronic Revolution”, as it truly is! These two (2) devices, properly applied, can and do dramatically simplify the complexity and content of a conventional hydronic heating system. Again, properly applied and supported by contemporary control systems provided by an “Intelligent” System Aquastat with idealized piping (plumbing) can further enhance performance, as our work has evidenced. Our development efforts and observations are reflected within the remainder of this presentation.

    The Delta-T ECM Variable Speed, Intelligent, Multi-Temperature-Sensing Circulator is a marvel of applied technology. Its ability to sense, measure and maintain a preset temperature differential in a hydronic circuit virtually optimizes heat transfer efficiency in a single, automatic step. Further being able to accommodate varying demands from multiple zones (circuits) virtually seamlessly as we have evidenced places it as the heart of any hydronic system. Using an automotive analogy we slogan that we are putting an ‘Automatic Transmission’ on a Boiler, but doing it hydronically.

    Now pair this Taco® Delta-T ECM Circulator with a compliment of their Zone Sentry® Zone Valves and you dramatically reduce energy consumption while gaining some further fuel efficiency. As Taco® promotes we are seeing distribution power consumption drops to 11-13 watts and in another instance to 8 watts during normal operation! Compare these with 80 watts for a single Taco® 007 and 21 watts each  for a Heat Motor Zone Valve. (The Zone Sentry® uses 11 watts, and then only in a brief actuator “charging cycle”.) Hydronic heating system power consumption is virtually never considered in design, but it should and furthermore must be!

    Piping is the pride of any plumber (ourselves included) yet in so being can become a detriment to system performance. To this point we offer that hydronic convection (the natural attribute of heated water to rise, and cooler fall) is not considered as a positive contribution to system performance, but an attribute to be controlled. As we have witnessed in our design effort however, natural convection is a measurable asset, particularly when configuring piping and placement to maximize its effect. Near-boiler piping, to employ the trade term, is crucial to maximizing hydronic performance. Compacted packaging of correct pipe sizing and layout close to the boiler displays great natural (non-powered) circulation that may not only supplement but also heat at reduced levels. We had an early Delta-T Circulator failure on one of our “beta” installations that was not discovered for an estimated 2-3 days! How’s that for convection — like “paddling your canoe with the current”.

    When you fully integrate the “intelligent” Delta-T ECM Circulator, Zone Valves and Aquastat with idealized convection you come to the conclusion that hydronic system installation is no longer a process, but functionally becomes an Appliance. Our resultant “package” is contained within its boiler footprint plus minimal rear piping space. A designer need only define system capacity, number of zones, fuel type and exhausting to define the “appliance”. Further, the application lends itself to modularization, and thus to versatility by default. Not only do we significantly reduce the material content of a system, but its labor content and installation time as well.

    Now there is both a trade and consumer option, a virtual Hydronic Heating Appliance with a fixed cost and defined, superlative performance. Our work to date has been developing a “Package Delta-T ECM Hydronic (Oil) Heating System” that achieves its higher performance by incorporating Delta-T ECM Hydronic Distribution Technology with a high-mass, lower operating temperature boiler for optimized performance. But also recognize that Delta-T ECM Circulation will work on any fueled hydronic application, putting an “automatic transmission” on ANY boiler. This obviously reduces the size, content and complexity of the “Plumber’s Playground”, but to a net performance advantage in doing so.

    To summarize, a “Hydronic Heating Appliance” is in our near future, defined by technology and necessitated by the market, like it or not. Its Performance Specification will virtually determine system performance, unlike the potpourri of present practice. Our publicized contributions are documented on our website www.BoilersOnDemand.com.  Please note that our current and following product offerings are under Intelligent Property Protection (Patent Pending). We look forward to “Boilers On Demand” in the new “Plumber’s Playground”.


  • DELTA-T ECM HYDRONIC DISTRIBUTION – Really “Raising The Bar”!

    Heating and moving water (hydronics) is recognized as the most efficient method of creating and distributing warming energy. From the Roman Baths to Gravity Piped Hot Water Systems of a century ago natural convection of heated water provided a simple, if seemingly temperamental solution.

    Adding pumps (circulators) to heating water distribution has forever improved comfort an flexibility. However, their application has been less than ideal, utilizing only fixed-speed/capacity circulators, typically poorly applied to residential heating in particular. Using a “one size fits all” approach and swapping sizes to effect results has been a thorn to the trade suppliers.

    Applying switchable, multi-speed circulators has provided an interim solution to poor matching options. Further, measuring actual circulator zone supply and return temperature differentials with an infrared thermometer while selecting speed(s) has provided a more efficient solution. It’s still a less-than-ideal result, with a cost premium.

    The Delta-T (Differential Temperature Sensing) Variable Speed Circulator has been around for some years now, providing the idealized solution to heating distribution flow management. It has arguably fallen far short of its potential, burdened by high initial cost, audible operational “whine” and low speed “growling”. Occasional high load torque stalls further contributed to its unknown nature.

    Enter the ECM (Electronically Commutated Motor), the latest iteration of the “intelligent” Delta-T Variable Speed Circulator. The “heir apparent” is whisper quiet yet powerful, dramatically reduces power consumption with no “torque stalls”, displays great functional data and at a palatable cost. Taco® Comfort Solutions of Cranston, RI also claims up to 15% fuel savings along with an 85% energy drop with their 00e Series VT2218 ECM Circulator, pictured.

    Author’s Note: We former High-Tech Process Engineers were applying “Stepper Motors”, the ECM predecessors to Machine & Process Control over 40 years ago. Finally, the Heating World is getting some real tools to work with!

    The Delta-T Circulator is and has always been marketed as an enhanced replacement for a fixed or multi-speed circulator. Have a zone performance issue? Substitute a Delta-T and “tweak” it in. Problem fixed, within the constraints of the zone design and a 3X cost premium of course. This latest (and supplier exclusive) Taco® VT2218 is being very well received, breaking the “Cost-Performance Stigma” of its predecessors and counterparts. We love it!

    VT2218+ZV ultra-oil-1 HTPSuperstor

    As “High-Tech” Process and Manufacturing Engineers with a Heating Discipline we (Mercier Engineering) have further projected the Taco® Delta-T ECM VT2218 as a Dedicated System Circulator, the acknowledged INDUSTRY FIRST to do so! Reviewing its Technical Specifications the VT2218 is ideally suited to residential/light-commercial heating system applications, given that operational attributes can be accommodated. These are namely:

    1. Providing uniform heating performance under normal multi-zone demands.
    2. Simultaneously servicing an Indirect Water Heater (IWH) to optimize both domestic hot water (DWH) and heating water generation.
    3. Prioritizing DHW generation within varying area heating demands.
    4. Accommodating differential temperature branching such as radiant zone(s).
    5. Satisfying both current and future (planned expansion) demands without an efficiency penalty.
    6. Providing beneficial System Service & Reliability projections.

    Over the past fifty (50) years we have installed and monitored “conventional” hydronic (FHW) heating systems, focusing on component selections, their performance and service levels. This continual qualification process has yielded a set of Premium American Components with “zero-fail” histories, at the expense of other NAFTA, Euro & Chinese products.

    Recognizing the potential of Delta-T Hydronics Distribution as previously noted, about five (5) years ago began a concerted effort to select and qualify the dedicated system circulator application. Our independent work using three (3) successive iterations of Taco® VDT, HEC and VT/00e Products has yielded not only a viable, but a superlative Packaged Delta-T ECM Hydronic Heating Appliance™. Its performance is principally based on our Proprietary Near-Boiler Piping System that constitutes the basis of our Non-Provisional Intellectual Property Protection Submission (Patents Pending – USA & Canada).

    So what began as an “evolutionary” effort to apply a newly available “tool” in the resultant has approached a “revolutionary” one. Our Packaged Delta-T ECM Hydronic Heating System™ is actually a FHW Heating Appliance, an industry first! Placing the Delta-T ECM Circulator into a full hydronic (FHW) heating system we slogan as “Putting an ‘Automatic Transmission’ on a Boiler”. Coupling “intelligent” Taco Zone Sentry® valving (pictured), a “high-mass” boiler (Weil-McLain UO – pictured) and an integrated IWH (HTP SSU45 – pictured) dramatically reduce complexity and idealize hydronic system performance.

    In our introduction we referenced the “natural convection” (gravity heating) used by the Romans, et al that prefaced our “modern” hydronics. Our optimized Delta-T ECM System exhibits exceptional gravity convection qualities, continuing heating upon circulator disablement or with zone valve manual operation. Short of a full electrical outage significant gravity convection heating continues, providing a useful fail-safe protection feature.

    Now let us really “Raise The Bar”. Here is performance data taken from two (2) similar “beta test sites” in our grouping.

    100,000 BTUH System, Oil-Fired, 3-Heating Zones + IWH

    Attribute “Conventional” System Delta-T Hydronic System Comments
    System Efficiency (Est.) 87% (Boiler Only) 90++% (Aggregate) Combined Hydronic Efficiencies
    Mean Operating Temperature > 145°F (Est.) 132-140°F (Observed) Normal Heating Operation
    Distribution Power 165 Watts (Est.) 11-12 Watts (Observed) Equates to Taco® Claims
    Distribution Fuel Efficiency  N/A – 15% Consumption Per Taco® Claims
    Natural Convection  Minimal to Moderate Very Significant (Observed) Very Installation Dependent
    System Footprint < 35 Sq. Ft. 12 Sq. Ft. (Actual) Very Installation Dependent
    Construction/Life Low-Mass C.I. or Stl. + Copper High-Mass C.I. & Stl. Only  10 to 20 vs. 30+ Yrs. (Est.)
    Complexity/Maintenance/Skill Higher/Annual/Specialized Low/Bi-Annual/Standard Standard Controls Only
    System Installed Cost (Est.) $10,000+ (Est.) $7,500 (Quoted) Southern NH Region

    This is the new “Bar Height”.

    We challenge ANY Tradesman or System Installer to raise it.

    To Summarize:

    1. Delta-T ECM Hydronic Distribution is singly the most significant and cost-effective contemporary heating advancement.
    2. This technology is applicable to any fueled hydronic heating system with substantial packaging and cost benefits.
    3. System configuration using a Dedicated Delta-T ECM Circulator further reduces physical and technical complexity while idealizing hydronic performance.
    4. Our Packaged Delta-T ECM Hydronic Heating System™ is the first, true Hydronic Heating Appliance, considering its intrinsic architecture, performance and as-installed economics.
    5. This is the new Standard of Measure in Hydronic Heating.

    Author’s Note: Updated 06/12/2017


  • THE DELTA-T ECM CIRCULATOR — The “Automatic Transmission” for Boilers

    After speaking on-site  with a local customer about his system, he inquired as to what else we were doing. A mistake on his part.

    Both of us having differing technical backgrounds I launched into an inspired dissertation of our application of Delta-T ECM Circulation to Residential FHW Heating Systems. Obviously very interested, a running Q & A exchange of increasing technical depth ensued to the point of my noting he was developing that “deer in the headlights” look of incomplete understanding.

    We engineering types have a terrible habit of technically overloading our audiences, not as an “ego-trip”, but to inform as effectively as possible — we think!

    Needing to salvage the situation I paused, desperately searching for that inspired “bolt of lightening” to strike and clarify the atmosphere. By seeming grace, it came immediately! “I’m putting Automatic Transmissions on Boilers.” Yeah”, he responded, “that makes complete sense. Good idea!” Our further conversation became an analogy of FHW Heating Systems to Automobiles, surprisingly clearing our technical disparages. To expound …..

    After all, hot water boilers and automobile engines are both truly “heat engines”. An automobile engine must convert as much fuel combustion energy into mechanical propulsion power as possible via pistons, crankshafts, etc. Less than 60% becomes useful power, the remainder is dissipated as waste heat. The hot water boiler on the other hand necessarily converts its fuel combustion energy directly into useful heat at up to 97% efficiency!

    The automobile uses a transmission to adapt its mechanical power to control vehicle propulsion. A variety of gears, pumps, valves, etc. are used to accomplish this. The hot water boiler conversely needs only to move heated water (via a pump) exactingly to ideally acclimate our heated areas and (optionally) our domestic hot water (DHW).

    The Delta-T ECM (Differential Temperature) Variable Speed Circulator (Pump) is that ideal “boiler transmission” that delivers heated water most efficiently to maintain our comfort. So efficiently does it do so as to reduce system fuel consumption by up to 15% and electrical consumption by up to 85% as documented by Taco, Inc. Published Testing Results.

    No longer is heating system efficiency measured solely (and inaccurately) by the Boiler AFUE (Annual Fuel Utilization Efficiency) Rating, but the aggregate of Boiler, Distribution and Radiation Efficiencies. There are THREE (3) Elements in a hydronic heating system! Just as in Sulky Racing, it’s the combination of the horse, the jockey and the buggy that wins races.

    Even more exciting  is the opportunity provided by the Delta-T ECM Circulator to most efficiently configure a FHW Heating System, which we have done very effectively. Refer to our other, recently published Delta-T Blogs on this site that detail our development, field testing and observations of our systems.

    Our “Packaged Delta-T ECM Hydronic Heating Appliance™” (Patents Pending) exhibits the following attributes in direct comparison to the typical “conventionally installed” system:

    1. Has a higher Combined Boiler AFUE and Delta-T ECM Distribution (System) Efficiency than achievable with any “conventional” system configuration.
    2. Consumes less fuel and electrical power than any equivalently sized system.
    3. Our Integrated Boiler/Indirect Water Heater System occupies 1/3 to 1/2 the floor-space of others.
    4. Our proprietary Fully-Iron & Cast near-boiler piping maximizes durability and distribution performance using fewer materials.
    5. Further combining a High-Mass Boiler with an All-Stainless Indirect Water Heater assures a dramatically projected economic life (30 years or more?).
    6. A truly universal, multi-fuelable Appliance. Just change the burner and not the system!
    7. Provides, Simple, Durable, Efficient and Cost-Effective FHW Heating.

    So yes, we do put “Automatic Transmissions” on Boilers!

    Author’s Note: Updated 07/23/2018